YiLink Releases yiCali Automated Temperature Calibration System V0.5.0

2026-10-09YiLink Releases yiCali Automated Temperature Calibration System V0.5.0

Making temperature calibration more automated, records clearer, and reports easier to deliver.

Beijing YiLink Technology Co., Ltd. has officially launched yiCali Automated Temperature Calibration System V0.5.0. Purpose-built for precision temperature calibration tasks, the software integrates work-order management, dual-channel device connectivity, setpoint configuration, automated stabilization and sampling, deviation correction, and certificate generation into an intuitive, guided workflow.

Automated Calibration with Complete Audit Trail

After connecting the tested instrument and reference standard, users can batch-configure temperature setpoints and soak times. The system drives heating/cooling automatically, tracks stabilization conditions, and executes countdown sampling once thermal equilibrium is reached. If retesting is necessary, individual setpoints can be re-run or wiped without discarding the entire sequence.

Deviation correction features a structured three-step protocol: clearing outdated parameters, writing new offsets, and reading back data for verification. An integrated event log captures connection states, thermal control phases, stabilization triggers, and register write results for full metrological auditability.

Automated Reporting for Swift Delivery

Upon test completion, users can select report templates and review a true-to-life A4 format preview before exporting tamper-proof PDF certificates and raw CSV datasets. Reports allow customized customer details, calibration locations, ambient temperature/humidity, and multi-tier electronic signatures for operators, checkers, and authorized signatories.

For compatible instruments, yiCali also delivers automated temperature fluctuation testing compliant with metrological guidelines.

yiCali Automated Calibration Interface

Figure 1: Automated Deviation Calibration — Real-time temperature readouts, stability indicators, progress bar, and calibration logs.

yiCali Certificate Preview Interface

Figure 2: Certificate Preview — Template selection, WYSIWYG A4 pagination inspection, and information entry.

yiCali's guided calibration procedures, traceable data logging, and standardized report generation empower rigorous, verifiable metrological operations.

For more technical details and online access, please visit Beijing YiLink Technology official website: https://yilink.tech.

Beijing YiLink Technology Co., Ltd.

Address: Room 8-808, Yard 19, Xincheng East Street, Mentougou District, Beijing

Phone: 18511281466

Email: tiandezhen@sina.com

Contact QR Code
Contact Us

Copyright ©2026 Beijing YiLink Technology Co., Ltd.. All Rights Reserved.